VRV-III – OUTDOOR UNIT

ODU-2

VRV-III – OUTDOOR UNIT

VRV III-Designed for large-sized buildings

Daikin proudly introduces the VRV III series, which is well-suited to large-sized buildings. This air conditioning system provides outdoor units that extend air conditioning capacity up to 54 HP. It also incorporates numerous outstanding features, such as a wide range of outdoor and indoor units, long actual and total piping length, and high external static pressure. The VRV III series provides the power and versatility you need for flexible

design and easy installation in large-sized buildings. The Heat Recovery Series also enables simultaneous cooling and heating, meeting the various needs for temperature control.

VRV III-C-Designed for low outdoor temperature use

Daikin has extended its range of VRV air conditioning systems with the technologically advanced VRV III-C inverter controlled heat pump system, designed specially for installation in cold climates. The VRV III-C provides highly efficient heating in outdoor temperatures as low as -25 °C.

It features newly developed 2-stage compression technology, providing better heating performance.

VRV III-Designed for high outdoor temperature use

The VRV III series has specially designed models for high outdoor temperatures, with an extensive capacity ranging from 8 to 36 HP. Cooling operations in this range can be performed with outdoor temperatures as high as 50°C. This series incorporates Daikin’s latest technologies,

including long piping and high external pressure, to meet the diverse needs of our customers.

 

Array

Array

  • Specifications
  • Features
Models
VRV III ODU SPECIFICATION
NORMAL TYPE HP ODU  DIMENSION [HxWxD] POWER SUPPLY TONS Multi Kit Gas pipe Lqd pipe
RXYQ5PAY6 5 1680x635x765 380-415 v / 50 H z / 3 phase                                        To OUT DOOR LOCATION 4.03 15.9 9.5
RXYQ8PRY6/PAY6 8 1680x930x765 6.46 19.1 9.5
RXYQ10PRY6/PAY6 10 1680x930x765 8.1 22.2 9.5
RXYQ12PRY6/PAY6 12 1680x1240x765 9.66 28.6 12.7
RXYQ14PRY6/PAY6 14 1680x1240x765 11.53 28.6 12.7
RXYQ16PRY6/PAY6 16 1680x1240x765 13 28.6 12.7
RXYQ18PRY6/PAY6 18 1680x1240x765 14.13 28.6 15.9
RXYQ20PRY6/PAY6 20 (8+10) 1680x930x765 + 1680x1240x765 16.1 BHFP22P100 28.6 15.9
RXYQ22PRY6/PAY6 22(10+12) 1680x930x765 + 1680x1240x765 17.73 28.6 15.9
RXYQ24PRY6/PAY6 24 (8+16) 1680x930x765 + 1680x1240x765 19.43 34.9 15.9
RXYQ26PRY6/PAY6 26 (8+18) 1680x930x765 + 1680x1240x765 20.56 34.9 19.1
RXYQ28PRY6/PAY6 28 (10+18) 1680x930x765 + 1680x1240x765 22.23 34.9 19.1
RXYQ30PRY6/PAY6 30 (12+18) 1680x1240x765  + 1680x1240x765 23.8 34.9 19.1
RXYQ32PRY6/PAY6 32 (16+16) 1680x1240x765  + 1680x1240x765 25.93 34.9 19.1
RXYQ34PRY6/PAY6 34 (16+18) 1680x1240x765  + 1680x1240x765 25.93 34.9 19.1
RXYQ36PRY6/PAY6 36 (18+18) 1680x1240x765  + 1680x1240x765 25.93 41.3 19.1
RXYQ38PRY6/PAY6 38 (8+12+18) 1680x930x765+1680x1240x765  + 1680x1240x765 25.93 BHFP22P151 41.3 19.1
RXYQ40PRY6/PAY6 40 (8+12+18) 1680x930x765+1680x1240x765  + 1680x1240x765 25.93 41.3 19.1
RXYQ42PRY6/PAY6 42 (8+16+18) 1680x930x765+1680x1240x765  + 1680x1240x765 25.93 41.3 19.1
RXYQ44PRY6/PAY6 44 (8+18+18) 1680x930x765+1680x1240x765  + 1680x1240x765 25.93 41.3 19.1
RXYQ46PRY6/PAY6 46 (10+18+18) 1680x930x765+1680x1240x765  + 1680x1240x765 25.93 41.3 19.1
RXYQ48PRY6/PAY6 48 (12+18+18) 1680x1240x765  + 1680x1240x765+1680x1240x765 25.93 41.3 19.1
RXYQ50PRY6/PAY6 50 (14+18+18) 1680x1240x765  + 1680x1240x765+1680x1240x765 25.93 41.3 19.1
RXYQ52PRY6/PAY6 52 (16+18+18) 1680x1240x765  + 1680x1240x765+1680x1240x765 25.93 41.3 19.1
RXYQ54PRY6/PAY6 54 (18+18+18) 1680x1240x765  + 1680x1240x765+1680x1240x765 25.93 41.3 19.1
VRV III Heat Pump and Heat Recovery Units. Manual includes information on installation preparations, piping and wiring work, field setting and safety considerations.